MaiMaiB2B

搜索关键字:optical

17条optical相关产品信息

厂家直供光纤音频线u音响电视连接线optical接口toslink光纤线

4.50
2020/11/22 23:13:16
产品简介:塑料光纤的一个重要应用就是用于各种数字音频跳线。1987年日本电子工业协会建立数字音频跳线标准。在短距离一般为5米内,在功放和内置的数字模拟转化器和数字音响如CD/MD/DAT播放器以及BS调谐器之间以6Mbps进行信号传输。塑料光纤不受任何噪音干扰有助于创造高品质声音。 ?????? TOSLINK是东芝连接(Toshiba Link)的缩写,也是一种标准光学数字音频接口,日本厂商在CD机、MD机上普遍采用。用于在各种器材之间,通过一种光导体,利用光作载体来传送数字音频信号(左右声道或多声道)。TOSLINK可以使用塑料光纤做塑料光纤音频跳线。常用标准的直径为?1.0mm、数值孔径(NA)0.5的PMMA芯塑料光纤,护套为(阻燃)PVC 产品特点: 小传输损耗,误码率(只有2%左右) 体积小,柔软可绕性好、抗冲击 安装简便、成本低廉 重量轻、不导电、性能稳定 排除无线电波和电磁干扰 数据传输效率高、保密性高 适用范围: 多媒体音响系统 3D、4D高清数字影院,数字成像系统 电视机,音响,回音壁,蓝牙盒子等产品...
深圳权恒光电技术有限公司

Different sizes of optical filters

0.00
2022/6/12 6:43:57
产品简介:Filte are designed by their manufacture to tramit or absorb different wavelengths of light. And they are widely used in scientific experiments and industrial applicatio where that change is necessary. VY Optics Photoelectric Technology Co.,Ltd. can supply a full range of filter. They are short pass Filter, long pass Filter, band pass Filter, ultraviole Filtert, infrared Filter, heat absorbing Filter, and color temperature conveion filte. We use material by China to Schott, Hoya, and other manufacture to process them. Metallic films, colored glasses and thin dielectric films filter are all available per your requirements. Filte are designed by their manufacture to tramit or absorb different wavelengths of light. And they are widely used in scientific experiments and industrial applicatio where that change is necessary. Color Separation Filter,Neutral Deity Filter,Filter,Short/Long Wave Pass Filter,Bandpass Filter and Interference Filter Specification of our color filter as follow: Material:Filter Glass,BK7 Dimeion: 4mm-160mm - 0.20mm Squares/Rectangles:1mm-165mm Thickness:0.5mm-4mm Thickness tolerance:+/-0.01mm-0.1mm Paralism: Up to 3 Arc minutes Edges:Fine Ground Flatness:Up to Lambda/10...
吉林省武圆光电科技有限公司

BK7 optical ball lens /half ball lens

0.00
2022/6/12 6:43:59
产品简介:Spherical Ball Lees are commonly used for laser collimating and focusing, laser-to-fiber coupling, fiber-to-fiber coupling, and fiber-to-detector coupling. Larger spheres are easier to handle and ease the seitivity of tralational alignment. However, smaller spheres has the benefit of fitting into smaller packages. Ball lees are highly polished spheres made of optically traparent homogeneous materials. Carefully controlled manufacturing process produces spheres with precise diamete and uurpassed surface quality....
吉林省武圆光电科技有限公司

Optical cylindrical lens with coating

0.00
2022/6/12 6:44:00
产品简介:Plano-convex cylindrical le,plano-concave cylindrical le,bi-convex cylindrical le,bi-concave cylindrical le,meniscus cylindrical le,long cylindrical le,special cylindrical le etc.. Specifiction of our cylinderical le as follow: *Material BK7 or other optical materials *Dimeion Tolerance +0.0 -- -0.1mm *Center Thickness +/-0.1mm *Focal Length Tolerance+/-1% *Surface Quality:20/10 *Surface Figure lambda/2 at 633nm on plano side *Clear Aperture >90% *Chamfer 0.25mm at 45 degree typical...
吉林省武圆光电科技有限公司

All kinds of optical CCTV lens

0.00
2022/6/12 6:44:01
产品简介:We supply optical le for optical itrument.Main optical lees include optical cylindrical le,optical spherical le,optical aspherical le,optical prism,optical filter le,optical grating,optical windows,optical mirror,optical components,camera le,fisheye le,wide angle le,telephoto le,projector le,adapter ring,adapter tube,custom le,OEM etc.. Specification of our optical le as follow: *Material BK7 or other optical materials *Dimeion Tolerance +0.0 -- -0.1mm *Center Thickness +/-0.1mm *Focal Length Tolerance+/-1% *Surface Quality:20/10 *Surface Figure lambda/2 at 633nm on plano side *Clear Aperture >90% *Chamfer 0.25mm at 45 degree typical...
吉林省武圆光电科技有限公司

ABI光学贴膜带刮板 4313663MicroAmp Optical Adhesive Film Kit

0.00
2022/6/12 8:21:58
产品简介:4313663 MicroAmp? Optical Adhesive Film Kit 北京ABI 4472908染料法实时荧光定量试剂盒 SYBR? Select Master Mix, 1-Pack (1 x 5 mL) 北京ABI MicroAmp Fast 八联管, 0.1 ml, 125条 货号 描述 包装 人民币 96反应板 N8010560 MicroAmp 96-well Rxn Plate 0.2ml 10块/盒 ¥1002.00 4306737 MicroAmp? Optical 96-Well Reaction Plate with Barcode 20块/盒 ¥1826.00 4346906 MicroAmp Fast Optical 96-Well Reaction Plate with Barcode 0.1ml 20块/盒 ¥1283.00 4375816 Fsat Optical 48-WELL Plate 20块/盒 ¥850.00 384孔板 4309849 MicroAmp Optical 384-Well Reaction Plate with Barcode 50块/盒 ¥4571.00 4326270 MicroAmp Optical 384-Well Reaction Plate with Barcode 500块/盒 ¥33990 光学贴膜 4360954 Optical Adhesive Cove 25片/盒 ¥1019.00 4311971 Optical Adhesive Cove 100片/盒 ¥3234.00 4313663 Optical Adhesive Cove Applicator 20片/盒 ¥965.00 4375928 48-WELL Optical Adhesive Cove 25片/盒 ¥908.00 4375323 48-WELL Optical Adhesive Cove 100片/盒 ¥2871.00 八连排管 4316567 MicroAmp Optical 8-Tube Strip 0.2 ml 125排/盒 ¥1543.00 4358293 MicroAmp Fast 8-Tube Strip 0.1 ml 125排/盒 ¥1271.00 八连排盖 4323032 MicroAmp Optical 8-Cap Strip 300排/盒 ¥1634.00 PCR-0208-C 0.2mlPCR八排管 125排/包 ¥735.00 PCR-02CP-C 0.2mlPCR八排管鼓盖 125排/包 ¥158.00 PCR-2CP-RT-C 0.2mlPCR八排管平盖 125排/包 ¥265.00 2014年底促销 货号 名称 促销价 4313663 MicroAmp? Optical Adhesive Film Kit(20cove) 400.00 4311971 MicroAmp? 96-Well Optical Adhesive Film, 100 films 1412.00 4360954 MicroAmp? 96-Well Optical Adhesive Film, 25films 446.00 4306311 MicroAmp? Clear Adhesive Film,100films 800.00 4306737 MicroAmp? Optical 96-Well Reaction Plate with Barcode (20 PLT) 885.00 4326659 MicroAmp? Optical 96-Well Reaction Plate with Barcode (500 PLT) 12000.00 4316813 MicroAmp? Optical 96-Well Reaction Plate- No Barcode (500 PLT) 12000.00 N8010560 MicroAmp? Optical 96-Well Reaction Plate - No Barcode (10PLT) 350.00 4346906 MicroAmp? Fast Optical 96-Well Reaction Plate with Barcode (20 plates) 545.00 4366932 MicroAmp? Fast Optical 96-Well Reaction Plate with Barcode (200 plates) 4800.00 4316567 MicroAmp?Optical 8-Tube Strip (0.2 mL) 642.00 4323032 MicroAmp? Optical 8-Cap Strip 679.00 4358293 MicroAmp? Fast 8-Tube Strip, 0.1 ml 545.00 4309849 MicroAmp? Optical 384-Well Reaction Plate with Barcode (50 plates) 1680.00 4326270 MicroAmp? Optical 384-Well Reaction Plate with Barcode (500 plates) 12500.00 4343814 MicroAmp? Optical 384-Well Reaction Plate with Barcode(1000PLT) 24000.00 4343370 MicroAmp? Optical 384-Well Reaction Plate(1000PLT) 23000.00 4375816 MicroAmp? Fast Optical 48-Well Reaction Plate with Barcode (20) 366.00 4375323 MicroAmp? 48-Well Optical Adhesive Film (100) 1234.00 4375928 MicroAmp? 48-Well Optical Adhesive Film (25) 390.00 4483316 MicroAmp? EnduraPlate? Optical 384-Well Multicolor Reaction Plates with Barcode(5PLT) 220.00 4483285 MicroAmp? EnduraPlate? Optical 384-Well Clear Reaction Plates with Barcode(20PLT) 880.00 4483315 MicroAmp? EnduraPlate? Optical 384-Well Yellow Reaction Plates with Barcode(20PLT) 880.00 4483320 MicroAmp? EnduraPlate? Optical 384-Well Blue Reaction Plates with Barcode(20PLT) 880.00 4483321 MicroAmp? EnduraPlate? Optical 384-Well Red Reaction Plates with Barcode(20PLT) 880.00 4483322 MicroAmp? EnduraPlate? Optical 384-Well Green Reaction Plates with Barcode(20PLT) 880.00 4483355 MicroAmp? EnduraPlate? Optical 96-Well Multicolor Reaction Plates with Barcode(5PLT) 182.00 4483343 MicroAmp? EnduraPlate? Optical 96-Well Blue Reaction Plates with Barcode(20PLT) 730.00 4483349 MicroAmp? EnduraPlate? Optical 96-Well Green Reaction Plates with Barcode(20PLT) 730.00 4483350 MicroAmp? EnduraPlate? Optical 96-Well Red Reaction Plates with Barcode(20PLT) 730.00 4483354 MicroAmp? EnduraPlate? Optical 96-Well Clear Reaction Plates with Barcode(20PLT) 730.00 4483395 MicroAmp? EnduraPlate? Optical 96-Well Yellow Reaction Plates with Barcode(20PLT) 730.00 4483493 MicroAmp? EnduraPlate? Optical 96-Well Fast Multicolor Reaction Plates with Barcode(5PLT) 140.00 4483485 MicroAmp? EnduraPlate? Optical 96-Well Fast Clear Reaction Plates with Barcode(20PLT) 560.00 4483486 MicroAmp? EnduraPlate? Optical 96-Well Fast Blue Reaction Plates with Barcode(20PLT) 560.00 4483487 MicroAmp? EnduraPlate? Optical 96-Well Fast Green Reaction Plates with Barcode(20PLT) 560.00 4483492 MicroAmp? EnduraPlate? Optical 96-Well Fast Red Reaction Plates with Barcode(20PLT) 560.00 4483495 MicroAmp? EnduraPlate? Optical 96-Well Fast Yellow Reaction Plates with Barcode(20PLT) 560.00...
北京明阳科华生物科技有限公司

Optical Time Domain Reflectometer

0.00
2022/6/12 9:34:51
产品简介:PREFACE Thank you for using the Optical Time Domain Reflectometer produced by Ititute of CHINA! This product integrates high-grade, high-precision and advanced technology and has the highest performance-to-price ratio among similar products. Please read this Guide carefully for convenient use. We will assume trying our best to meet your needs as our respoibility to provide high quality measuring itruments for you and also bring you fit-class after-sale services. We always peist in “Good Quality, Satisfied Service” and promise to offer satisfied products and service for you. Welcome to inquire by: STATEMENT This Guide is the fit edition of the Optical Time Domain Reflectometer. The veion number is AV2.761.0056SS. The information contained in this Guide is subject to change without notice. The explanation right of all the contents and terms in this Guide belongs to Ititute of CHINA. Ititute of CHINA makes no warranty of any kind to this Guide, including but not limited to the implied warranties of merchantibility and adaptability for a particular purpose. Ititute of CHINA shall not be liable for erro contained herein or for incidental or coequential damages due to the practibility of this material or veion. The copyright of the Guide belongs to Ititute of CHINA. Other entities and individuals can’t change or juggle it without our permission, and don’t copy, and spread (including electronic filling, retrieval or tralating it into another language) for business benefits. If discovered, we have the right for legal action. STATEMENT Please don’t attempt to disassemble or modify any part upecified in this Guide. Self-disassembly may lower electromagnetic shielding efficiency and cause damage to the itrument, etc. to affect the reliability of the product. If under warranty, we will not provide free repair. CONTENTS Safety Requirements 1 Warnings for Use of Itrument 2 Precautio for Use of Itrument 2 Maintenance 3 Calibration Requirements 4 Warranty and Maintenance of Itrument 4 Chapter 1 Overview 5 1. Overview of Itrument …5 2. Composition of Itrument 5 2.1 Basic Composition 5 2.2 Optional OTDR Modules 6 2.3 Optional Accessories 7 3. Description of Itrument Panel 8 3.1 Front Panel of Itrument 8 3.2 Right Panel of Itrument 8 3.3 Back Panel of Itrument 9 3.4 Description of Panel Keyboard and Active Display 9 4. Description of Rechargeable Battery 10 Chapter 2 Main Screen 11 Chapter 3 Optical Power Meter Module 12 Chapter 4 Optical Source Module 14 Chapter 5 Visible Fault Locator Module 15 Chapter 6 Audio Detection Module 16 Chapter 7 Optical Time Domain Reflectometer (OTDR)-Operating Itruction 17 1. Description of Main Screen 17 2. Description of Event List Window 18 3. Overview of Menu Structure and Function 20 3.1 Structure and Function of Fit Menu 20 3.2 Brief Introduction of Operating Subwindow Menu 20 4. Description of OTDR Panel Key Function 21 Chapter 8 How to Use 24 1.Testing Optical Fiber Chain 24 1.1 Description of Test Modes, Paramete and Items 25 1.2 Set OTDR Test Conditio 32 1.3 Test Fiber Link 50 1.4 Analyzing Waveform Trace and Checking Event Table 51 2.Operation for Cuor and Test Trace 53 2.1 Move Cuor 53 2.2 Set Active Cuor 53 2.3 Zoom in & out and Initialize Waveform Trace 54 2.4 Move Waveform Trace Vertically 54 3. Measure Fiber Length and Loss 54 3.1 Measure Fiber Length 54 3.2 Measure Fiber Average Loss 55 3.3 Measure Splice Loss 56 3.4 Measure Reflection Loss 56 4. File Management 57 4.1 Save Waveform File 57 4.2 Read Waveform File 59 4.3 Delete Waveform File 60 4.4 Copy the Files between OTDR and USB DiskD Card 61 4.5 Clear the Traces Displayed on the Screen 62 5. Set Fiber Information 62 6.Set Reference Origin 64 7.Trace Selection and Comparison 64 8. View System Information 65 9. Print Test Report 66 10. Help 67 11. System Upgrade 68 12. Common Faults and Treatment 69 Chapter 9 Operating Principle 71 1. Operating Principle 71 2. Description of Event Point Type 71 Chapter 10 Technical Paramete 72 1. General Characteristics 72 2. Main Functio 72 3. Main Technical Specification 73 3.1 OTDR Function 73 3.2 VFL Function (Option) 73 3.3 Optical Power Meter Function (Option) 73 3.4 Optical Source Function (Option) 74 3.5 Vibration Detecting Function (Option) 74 Appendix A Cleaning Optical Output Port 75 Appendix B Direction for Use of the Stimulation Analysis Software 77 Appendix C Ordering information 81 Safety Requirements The following general safety precautio must be taken during all the phases of operation of this itrument. Failure to comply with these precautio or with the warnings and precautio specified elsewhere in this Guide will violate the safety standards of design, manufacture and intended use of the itrument. Ititute of CHINA assumes no liability for the customer’s failure to comply with these requirements. ENVIRONMENTAL CONDITIO Refer to the “Chapter 10 Technical Paramete” for the operating and storage environment of the itrument POWER SUPPLY Refer to “Chapter 10 Technical Paramete” for the requirements for working power supply of the itrument. Before power-on, please make sure the itrument has been set to match available supply voltage and all safety precautio have been taken. DON’T OPERATE IN AN INFLAMMABLE AND EXPLOSIVE ATMOSPHERE Do not operate the itrument in the presence of flammable gases or fumes. DON’T REMOVE ANY PART OF THE ITRUMENT WITHOUT APPROVAL Please don’t remove any part of the itrument without approval, other than as explained in this Guide. Component replacement and internal adjustments must be made only by Ititute of CHINA or its authorized service peonnel. Safety Terminology : It calls user’s attention to a procedure, operation mode, or the like. Failure to correctly operate or adhere to rules could result in peonal injury or damage to the itrument. : It calls user’s attention to a procedure, operation mode, or the like. Failure to correctly operate or adhere to rules could result in damage to all or part of the itrument. : It gives the information helpful for the use and maintenance of the itrument. Warnings for Use of Itrument External DC Power Supply External DC power supply must meet the following requirements: 17V~21V, >2.**, polarity: positive core. Use of overhigh voltage may damage the itrument. Internal Battery (1) The battery iide the itrument is special lithium battery. Use of other batteries may damage the itrument and endanger the peonal safety of use. (2) For safety, don’t disassemble battery pack to avoid short circuit; even don’t fiercely impact or put the battery into or close to fire and strong heat to avoid explosion. Laser Safety (1) The safety class of the laser of this itrument is: CLASS1 LASER PRODUCT: 21 CFR 1040.10 or CLASS 3A LASER PRODUCT: IEC 60825-1:Ed.2:2001. (2) Although up to safety standards, the output inteity of the laser of the itrument still may damage eyesight, so it shall be prevented from directly shooting at eyes. Please don’t directly look into the optical output connector of OTDR with eyes, or even the optical fiber tail during testing. When the VFL function of the itrument is activated, please don’t directly look into the output port of VFL optical source, or even the optical fiber tail at VFL port. Use of OTDR Never connect an optical fiber carrying any kind of optical signal to the test port of OTDR, otherwise, it could result in inaccurate measurement result and even permanent damage to the itrument. Please make sure that all the optical fibe under test are inactive. Precautio for Use of Itrument AC/DC Adapter Please use the adapter provided by Ititute of CHINA for power supply. Use of other type of adapter can damage the itrument. Internal Battery (1) For the best battery performance, the itrument shall be powered with internal battery fit at the beginning of use until the battery is exhausted, and then it can be charged 2~3 times. (2) If the battery has been in storage for a long time, it shall be charged and discharged circularly as above for the fit time use to achieve an optimum performance. (3) In order to prolong the life of internal battery, remove external power supply after charging. For a long-time use of external power supply, please remove the internal battery and keep it properly, before that, please charge it fit, and make charge-discharge cycle once every 3 months to eure battery performance. (4) If the itrument has not been used for a long time, please charge the battery to make charge-discharge cycle before use. For a long-time storage, remove the battery, before that, please charge it fit. During storage, make charge-discharge cycle once every 3 months to eure battery performance, otherwise excessive self-discharge of battery may cause damage to it. (5) The temperature range for long storage time (the storage time is longer than 6 months) of battery is: -20℃~45℃. The temperature range for short storage time (the storage time is shorter than or equal to 6 months)of battery: -20℃~60℃. (6) The temperature range of charging battery is 5℃~40℃. If ambient temperature is too high or too low, charging will stop automatically, which will cause unfilled charge. (7) The time of charging may not be too long, otherwise, it will reduce battery life and even damage it. (8) To achieve better performance and more accurate battery capacity indicator, please maintain a complete charge or discharge process, i.e. don’t discharge during charging; don’t charge during discharging. LCD Display (1) Don’t use any sharp object to press LCD, don’t give heavy impact to LCD, otherwise it may damage it. (2) Don't pollute LCD with any organic solvent or contaminant such as acetone, motor oil, antifreezing fluid, factice, etc., otherwise, it will cause LCD works abnormally. (3) Clean LCD with silk cloth or soft cloth. Don’t use organic solvent to clean it, otherwise, it may damage the LCD. Use of OTDR (1) There is precise and fragile ceramic locating core iide the optical output connector of the itrument, so please be sure to iert optical fiber plug gently and parallelly and align it with locating pin and then tighten it. (2) When performing measurement with this itrument, you must keep the iide and end face of optical output connector clean and avoid polluting the optical output connector with factice, etc. contaminant, otherwise, it will cause measurement error and even that the itrument is incapable of testing optical fibe. (3) If possible, please make the end of the optical fiber under test point to an unreflected object during testing. Maintenance (1) Please pack this itrument in original packing material when shipping to avoid serious impact and vibration. (2) Before using this itrument, please carefully check and make sure the itrument model is Optical Time Domain Reflectometer, the itrument has not evident damage on the surface and all accessories are complete. (3) Store the itrument under the ambient temperature range of -20℃~60℃ (please see “Internal Battery” for detailed storage temperature range of battery) in a dry and ventilating place without direct suhine. When the itrument will be stored for a long time, please remove the battery and perform regular check with poweron, and meanwhile, make charge-discharge cycle once every 3 months. (4) In order to prolong battery life, make charge-discharge cycle once every 3 months for long-time storage, for which, please discharge the battery completely fit and then recharge it. Calibration Requirements Validity of technical paramete depends on environmental conditio. Calibration validity period can be longer or shorter depending on the inteity, environmental conditio and itrument maintenance. You should determine an appropriate calibration validity period according to your needs. Under normal use, we recommend to calibrate Optical Time Domain Reflectometer once every year. Please dial service telephone for details. Warranty and Maintenance of Itrument (1) Warranty for the entire itrument (except battery and the following coumables) is 18 months and the warranty for battery is 3 months. The gifts given during product promotion are not within the scope of warranty. (2) The optical output connector, etc. parts of the itrument are coumables, so they are not within the scope of warranty. (3) Damage to the itrument or lower performance due to force majeure and human factor is not within the scope of warranty. (4) Lowering battery performance with the use of the itrument for a period belongs to normal battery loss, which is not within the scope of warranty. (5) The repair of itrument should be done by Ititute of CHINA or its authorized repair company. The disassembly and repair of this itrument by any other company or individual are all illegal, which will void warranty to the itrument, and meanwhile, Ititute of CHINA reserves the right to puue offender’s legal respoibility. (6) Unauthorized disassembly will void the warranty of the itrument automatically. Removal of fastening screws or seals will void the warranty of the itrument. Note: Ititute of CHINA reserves the right to make any change in the design or cotruction of Optical Time Domain Reflectometer at any time without any obligation or respoibility to perform free improvements or replacements whatsoever on products purchased. Accessories, including but not limited to indicator lamps and batteries etc. used for this product are not covered by the warranty herein. Chapter 1 Overview 1. Overview of Itrument Optical Time Domain Reflectometer (hereinafter referred to as OTDR) is a kind of multifunctional test itrument with high performance designed for FTTx network. This product is mainly used to measure the length, tramission loss, splice loss, etc. optical fiber’s physical characteristics of optical fibe and cables, and also can exactly locate the event and fault in fiber circuits. It is widely used for the engineering cotruction, maintenance test & emergency repair of optical fiber communication system and research & development and production test, etc. of optical fibe and cables. The appearance of OTDR adopts the most advanced integrative double-color double-material mould design technology in the industry, novel and beautiful, solid and durable, and also adopts the duplex operation mode of touchscreen and key-press, simple and convenient, easy-to-learn and easy-to-use; there is advanced antireflection LCD display unit iide and the operating interface is also visible even outdoor; the whole itrument has 4 optical ports to realize the optical power meter, VFL and single mode & multimode testing functio, the types of which can be changed at random in convenience for cleaning of optical fiber end face. This product has abundant external ports to externally connect with USB disk & printer and realize data communication with PC by two different USB ports. Test results can be stored in the itrument and also can be stored in SD card by SD port. There is lithium battery with large capacity iide the itrument so the itrument can work for more than 8 hou, suitable for long-time outdoor work. Besides the functio of OTDR, OTDR also can have the optional functio of optical power meter, optical source, visible fault locator (VFL) and audio detection, etc. Main functio and features of itrument: ? 0.8m extra-short event dead zone, easy to test optical fiber jumper; ? 45dB high dynamic range, 128k data sampling points; ? Most advanced integrative double-color double-material mould technology in the industry, solid and durable; ? Advanced antireflection LCD, visible display interface even outdoor; ? Many test modes, touchscreen and shortcut operation; ? Communication light auto monitoring function; ? Double USB ports for connection of external USB disk & printer and communication with PC via Sync Active software; ? Support Bellcore GR196 and SR-4731 file formats; ? WinCE windows operating system, an operating interface with many languages; ? Built-in optional visual fault locator (VFL), optical power meter, optical source, audio detection, etc. functio; ? The type of optical output connector of OTDR can be replaced randomly, end face is clean and convenient; ? Update of application software system, unnecessary to return it to original factory. 2. Composition of Itrument 2.1 Basic Composition The basic composition of OTDR is shown in Table 1-1. Table 1-1 Basic Composition of OTDR Item Name Quantity Mainframe OTDR 1 Standard Accessories Power adapter 1 Power line 1 User’s Guide 1 CD 1 Multifunctional fiber adapter SC, ST 1 Engineering plastic case 1 2.2 Optional OTDR Modules The optional modules of OTDR are showed in Table 1-2. Table 1-2 Optional Modules of OTDR Module No.1 Operating Wavelength Optical Fiber Type Dynamic Range2 (dB) Event Dead Zone3 (m) Attenuation Dead Zone3 (m) –1101 1,310nm Single mode 45 2 10 –1102 1,550nm Single mode 43 2 10 –1103 1,625nm Single mode 38 1 10 –1104 1,625nm (built-in filter) Single mode 36 1 10 –1105 1,650nm Single mode 38 1 10 –1106 1,650nm (built-in filter) Single mode 36 1 10 –1107 1,490nm Single mode 36 1 10 –1108 1,383nm Single mode 36 1 10 –1201 850nm Multimode 26 2.5 15 –1202 1,300nm Multimode 36 2 13 –2101 1,310/1,550nm Single mode 42 / 40 2/2 10/10 –2102 1,310/1,550nm Single mode 40 / 38 1/1 10/10 –2103 1,310/1,550nm Single mode 37 / 35 1/1 10/10 –2104 1,550/1,625nm Single mode 38 / 38 1/1 10/10 –2105 1,550/1,625nm (built-in filter) Single mode 36 / 36 1/1 10/10 –2106 1,550 /1,650nm Single mode 38 / 38 1/1 10/10 –2107 1,550 /1,650nm (built-in filter) Single mode 36 / 36 1/1 10/10 –2108 1,310/1,550nm Single mode 45 / 43 2/2 10/10 –2201 850nm/1,300nm Multimode 26 / 36dB 2.5/2 15/13 –3101 1,310/1,490/1,550nm Single mode 39 / 34/ 38 1/1/1 10/10/10 –3102 1,310/1,550nm/1,625nm Single mode 39 / 38 / 36 1/1/1 10/10/10 –3103 1,310/1,550nm/1,625nm (built-in filter) Single mode 37/ 36 / 34 1/1/1 10/10/10 –3104 1,310/1,550 /1,650nm Single mode 39 / 38 / 36 1/1/1 10/10/10 –3105 1,310/1,550/1,650nm (built-in filter) Single mode 37/ 36 / 34 1/1/1 10/10/10 –4001 850/1,300/1,310/1,550nm Single/ multi mode 24/34/34/34 2/2/1/1 15/13/10/10 –4101 1,310/1,490/1,550/1,625nm Single mode 35/32/34/34 1/1/1/1 10/10/10/10 –4102 1,310/1,383/1,550/1,625nm Single mode 35/32/34/34 1/1/1/1 10/10/10/10 Notes: 1. One and only one standard module must be selected.All specificatio are for a Ambient temperature of 23℃±2℃ with FC/UPC connector unless otherwise specified. 2. SNR=1, more than 500 averaging times, using 20us pulse. 3. Dead zone test mode (range ≤0.8km, 5 pulse), reflection loss ≥40dB, typical value 2.3 Optional Accessories The optio of OTDR are shown in Table 1-3. Table 1-3 Optio of OTDR No. Name Model or Specification Explanation 1 USB disk 2GB Save test data 2 SD card 2GB Save test data 3 Data synchronization tramission line Communicate with computer 4 Standby battery pack 6417LB-1191 Standby battery 5 FCC, FCT adapter Test the optical fiber of corresponding joint 6 Optical fiber patch cord FC/UPC to FC/APC Optical fiber patch cord 7 Optical fiber patch cord FC/UPC to SC/UPC Optical fiber patch cord 8 Optical fiber patch cord FC/UPC to ST/UPC Optical fiber patch cord 3. Description of Itrument Panel 3.1 Front Panel of Itrument 3.2 Right Panel of Itrument 3.3 Back Panel of Itrument 3.4 Description of Panel Keyboard and Active Display (Please see section 4 “Description of OTDR Panel Key Function” of Chapter 7 for details) 4. Description of Rechargeable Battery The battery in OTDR is special lithium battery. 4.1 Batter Indicator and Charge Indicator When the itrument is powered on, the battery indicator at lower right shows the current remaining capacity of battery, and charge indicator also appea. Meanwhile, the system information window also shows the percentage of current remaining capacity of battery. When the charge indicator appea, it indicates the itrument has been connected with external power supply and is using the external power supply to work, and meanwhile the battery is charged. When the charge indicator does not appear, it indicates the itrument is using internal battery to work. When the itrument is working with external power supply for charge, the power button is red; when the battery is charged fully, the power button is green; when the external power is cut off, the power button indicator lamp goes out. 4.2 Charging the Battery (1) The temperature range of battery charge is: 5℃~40℃. It will stop charging automatically in case of exceeding the temperature range during charging, which will cause that the battery is not fully charged. Overhigh temperature will cause damage to the battery and affect its life. (2) The charging time is less than or equal to 6 hou when this itrument is off. (3)The charging time is less than or equal to 8 hou when the itrument is on. (4) Overlong charging time will affect battery life and even cause damage to it. 4.3 Precautio In order to prevent the rechargeable battery from excessively discharging, the battery iide the itrument should be charged in time through external power adapter . Long-time excessive discharge of the rechargeable battery will affect battery life and even cause damage to it. Chapter 2 Main Screen OTDR can have the optional functio of optical power meter, optical source, visible fault locator (VFL) and audio detection, etc. as required. When function modules return to the main screen, the screen for function module selection will appear as shown in Figure 2-1. ? Touchscreen Operation: Press any one of the five butto, i.e. OTDR, OPM, Optical Source, VFL or Audio Detection in the screen to enter the operating interface of corresponding module so as to achieve its corresponding function. Press the drop-down button of default module to eject a selection box as shown at the left of the above figure, press the item required, so that the operating interface of the selected module can be entered directly after poweron next time. ? Default Module: After selection, the selected module interface will be entered after poweron next time. ? Key Operation: Press / to select any one of the five butto in the screen, and then press to enter corresponding module operating interface. Use / to move active cuor to the drop-dow of default module and then use / to select a module as default one for next poweron, after selection, the operating interface of the selected module can be entered directly for next poweron. ? Directly press the drop-down box of default module on the touchscreen to select one. ? Language Selection: Select the language of interface. Operate the touchscreen and keys as above. ? System Date: Change system date and press to confirm the change. ? Press the time item to be changed in the touchscreen, a small button will appear below the item, and then press the up and down button via touchscreen to change the selected time item. ? Use / to select the time item to be changed and then a small button will appear below the item; press / to change the selected time item. ? After change, press 【Enter】or to confirm the change. Chapter 3 Optical Power Meter Module If your itrument has the function of optical power meter, please press the button【Optical Power Meter】as shown in Figure 2-1 to enter the operating interface of optical power meter as shown in Figure 3-1. The functio and operatio of all menu butto are described as follows: ? 【Start】: Start or stop power meter test with the following three methods. ? Press this button to start the power meter module for test, meanwhile, the button tur to 【Stop】, press this button again to stop power meter test, then, this button tur to【Start】. ? Pressing the key on the keyboard can realize the above function. ? Press the key on the keyboard to move active cuor to menu bar as shown in the figure below, and then menu item will show a small button. Then, pressing will start or stop power meter test function. ? 【Wave】: Change the test wavelength of power meter. ? Press this button to change the test wavelength of power meter. ? Press the key on the keyboard to move active cuor to menu bar, and then menu item will show a small button. Use / to move the small button to this menu item and then press to confirm wavelength change. ? 【Setup】:Enter setup sub-menu as shown in the figure below. Press the menu button via touchscreen or use the keyboard to realize the function of each button with the same method as above. Setup sub-menu is also available by pressing the key on the keyboard. ? 【Range】: ? 【Times】: Press this menu button to eject the drop-down box for times selection, and select times by pressing touchscreen or / ? 【Reference】: Set the current measured value as reference value. ? 【dBm/W】: Set the current test mode as dBm test or mw test. ? 【Interval】: Set the interval of saving measured values. Selecting indicates there is no interval for saving values; otherwise, a measured value will be saved at the intervals selected. ? 【MemoryD】: Set storage path as memory or SD card. ? 【Return】: Return to previous menu. ? 【Abs./ Rel.】: Set the current data realization mode as relative or absolute mode. ? 【Zero】: Reset the power meter to zero. ? 【Save】:Used to save the test data of power meter. This menu item is only available in test state. In the test state of power meter, press this button (or use keyboard to select this item and then press to confirm) to save the data obtained in current test to file according to the set interval and save path. ? 【Return】: Exit from the operating interface of power meter to return to the main screen. Notes: The memory only can save a power meter data file -OPM.dat, therefore, when selecting memory as storage path, please pay attention to timely outputting data to SD card or USB disk, otherwise, the original file will be covered for next saving. Chapter 4 Optical Source Module If your itrument has the function of optical source, please press the button【Optical Source】as shown in Figure 2-1 to enter the operating interface of optical source as shown in Figure 4-1. The functio and operatio of all menu butto are described as follows: ? 【Start】: Start or stop optical source test with the following three methods. ? Press this button to start the optical source module for test, meanwhile, the button tur to 【Stop】, press this button again to stop optical source test, then, this button tur to【Start】. ? Pressing the key on the keyboard can realize the above function. ? Press the key on the keyboard to move active cuor to menu bar as shown in the figure below, and then menu item will show a small button. Then, pressing will start or stop optical source test function. ? 【Wave】: Change the test wavelength of optical source. ? Press this button to change the test wavelength of optical source. ? Press the key on the keyboard to move active cuor to menu bar, and then menu item will show a small button. Press / to move the small button to this menu item, then, press to confirm wavelength change. ? 【Mode】: Change the working mode of optical source. The working mode of optical source is CW, 270Hz, 1kHz and 2kHz ? Pressing this button will change the working mode of optical source. ? Press the key on the keyboard to move active cuor to menu bar, and then menu item will show a small button. Press / to move the small button to this menu item, then, press to confirm the change of working mode. ? 【Return】: Exit from the operating interface of optical source function to return to the main screen. Chapter 5 Visible Fault Locator Module If your itrument has the function of VFL, please press the button【VFL】 as shown in Figure 2-1 to enter the operating interface of VFL as shown in Figure 5-1. The functio and operatio of all menu butto are described as follows: ? 【Start】: Start or stop VFL module test with the following three methods. ? Press this button to start the VFL module for test, meanwhile, the button tur to【Stop】, press this button again to stop VFL test, then, the button tur to 【Start】. ? Pressing the key on the keyboard also can realize the above function. ? Press the key on the keyboard to move active cuor to menu bar as shown in the figure below, and then menu item will show a small button. Then, pressing will start or stop VFL test function. ? 【Mode】: Change the working mode of VFL. The working mode of VFL is CW, 1Hz and 0.5Hz ? Pressing this button will change the working mode of VFL. ? Press the key on the keyboard to move active cuor to menu bar, and then menu item will show a small button. Press / to move the small button to this menu item, then, press to confirm the change of working mode. ? 【Return】: Exit from the operating interface of VFL function to return to the main screen. Chapter 6 Audio Detection Module If your itrument has the function of audio detection, please press the button 【Audio Detection】as shown in Figure 2-1 to enter the operating interface of Audio Detection Module as shown in Figure 6-1. The functio and operatio of all menu butto are described as follows: ? 【Start】: Start or stop audio detection module test with the following three methods. ? Press this button to start the audio detection module for test, meanwhile, the button tur to【Stop】, press this button again to stop audio detection test, then, the button tur to 【Start】. ? Pressing the key on the keyboard also can realize the above function. ? Press the key on the keyboard to move active cuor to menu bar as shown in the figure below, and then menu item will show a small button. Then, pressing will start or stop audio detection test function. ? Volume Control: Press the key / on the keyboard to increase volume; press the key / on the keyboard to reduce volume. ? 【Return】: Exit from the operating interface of audio detection function to return to the main screen. Chapter 7 Optical Time Domain Reflectometer (OTDR)-Operating Itruction Press the button 【OTDR】as shown in Figure 2-1 to enter the operating interface of OTDR as shown in Figure 7-1. The operating interface of OTDR is composed of main screen and operating subwindow. After the itrument ente the operating interface of OTDR module, the display will show the main screen of OTDR as shown in Figure 7-1. The menu bar in the main screen shows menu items. Press different menu butto to enter corresponding sub-menus or finish corresponding functio. 1. Description of Main Screen The schematic of main screen is shown in Figure 7-1. (1): Current system clock (2): Display of test results The contents of displaying correspond to test items. Test results are calculated according to the position of current cuor. (3): Entirely display trace It always displays the entire waveform of trace. (4): Reference point (5): Current active cuor Active cuor is red, which can be moved by / or pressing touchscreen. The other cuo are black. Active cuor can be set circularly by among the cuo on the screen. (6): The distance between active cuor and reference point (7): Display of current average times No average times are displayed in real-time test mode. (8): Menu bar In the main interface, the menu bar displays menu items. (9): Display of test conditio It displays the current test range, wavelength, pulse width, test mode, etc. test conditio. (10): Name and storage date of current file If the current trace is that saved in the current file, it will display the name and storage date of current file. (11): Origin distance position The distance between the current set reference origin and the test port of OTDR *1 (12): Indicator of connection of external adapter It indicates external adapter has been connected and the itrument is using external power supply to work. (13): Indicator of current battery capacity It indicates the current remaining battery capacity. (14): Indicator of current test trace color It indicates the line color of trace of current serial number. *2 (15): Vertical scale (dB/) (16): Horizontal scale (m/ or km/ or ft/ or kft/) (17): Icon of indicating current active test trace: Blue color indicates the current active trace is Trace 1; dark green color indicates the current active trace is Trace 2; red color indicates the current active trace is Trace 3. 2. Description of Event List Window In the main screen displayed in Figure 7-1, press the button【Analyse】to analyze the current trace and display event list. If the current event table has contents, press the button 【Event Table】to show event list. The event list window is shown in Figure 7-2. All the contents in the event list are shown as follows: (1) Event Type: indicates this event point is down event point. : indicates this event point is up event point. : indicates this event point is reflection event point. : indicates this event point may be the end of optical fiber. (2) No: The serial number of current event point. (3) Dis (km): The distance between this event and reference origin. (4) Average (dB/km): The average loss of the optical cable before the current event point. (5) Splice Loss (dB): The splice loss measured at current event point * indicates the current tested splice loss value is larger than the set pass threshold of splice loss. (6) Reflection Loss (dB): The reflection loss measured at current event point * indicates the current tested reflection loss value is larger than the set pass threshold of reflection loss. (7) Link (dB): The total loss of the fiber section from current event point to reference origin. 3. Overview of Menu Structure and Function 3.1 Structure and Function of Fit Menu Main screen displays main menu bar by default, including seven menu butto as shown in Figure 7-3. All the button functio on the menu bar are described as follows: (Pressing corresponding menu item will realize the following function. See “Chapter 8 How to Use OTDR Module) 【System】: Enter system sub-menu to realize the functio of system information display, touchscreen calibration, system program update, help information display and return to main screen (interface of operating module selection), etc. 【Setup】: Enter parameter setup sub-menu to realize the functio of OTDR test condition setup, reference origin setup, optical cable information setup, etc. 【Start】: This button is used to control optical fiber test of OTDR or stop test. Pressing this button tur the button to 【Stop】, then, OTDR will test the optical fiber under test according to the set test condition; Pressing this button again tur the button to【Start】and OTDR will stop test If in average test, auto test and dead zone test mode, the test is finished, this button will turn to 【Start】automatically and meanwhile OTDR stops test. 【File】: Enter file operation sub-menu to realize the functio of reading, saving, deleting file, printing and traferring file and clearing the trace displayed on screen, etc. 【Analyse】: Analyze the current trace to give event list. If event point is unavailable, a prompt will be given. 【Event Table】: Displaying event list and event operation sub-menu to realize the functio of deleting, adjusting and adding event point and modifying event analyse threshold, etc. 【Trace 1】: Display trace selection window in which the trace number can be selected to switch the current active trace among Trace 1, 2 & 3. Trace 1 is blue; Trace 2 is dark green and Trace 3 is red. 3.2 Brief Introduction of Operating Subwindow Menu Press menu butto in the main menu bar to enter different sub-menus (or executing corresponding function), press different sub-menu butto in each sub-menu bar to eject corresponding operating window to finish different functio, such as, saving, reading, deleting and copying file and viewing event list, setting OTDR test paramete, displaying system and help information, etc. Please see “Chapter 8 How to Use OTDR Module” for details....
青岛东方佳讯光电信息有限公司

MPO防尘塞MTP防尘塞 /SFP+ Active Optical Cable/AOC防尘塞

0.30
2023/12/22 13:54:44
产品简介:产品广泛用于工控光纤/网络通讯/光模块/光电子产品,质量保证,可按客人图纸订做各种规格,欢迎来电咨询。 1.材质硅胶 2产品符合RoHS要求 3产品防静电,防火! The product widely use light module/optoelectronic products, quality assurance, can press the guest to order various kinds of specificatio, drawings, welcome to inquire. 1. The material silica gel 2 products comply with RoHS requirements 3 anti-static products, fire!...
东莞市速网五金制品有限公司

CWDM 10G XFP Optical Module

350.00
2024/1/22 9:34:09
产品简介:Description Baudcom CWDM XFP Traceiver exhibits excellent wavelength stability, supporting operation at 100 GHz channel, cost effective module. It is designed for 10G CWDM SDH, 10GBASE-ZR and 10G Fiber- Channel applicatio. The traceiver coists of two sectio: The tramitter section incorporates a colded EML laser. And the receiver section coists of a APD photodiode integrated with a TIA. All modules satisfy class I laser safety requirements. Baudcom CWDM XFP traceiver provides an enhanced monitoring interface, which allows real-time access to device operating paramete such as traceiver temperature, laser bias current, tramitted optical power, received optical power and traceiver supply voltage. Features ¨ Wavelength selectable to ITU-T standards covering CWDM grid ¨ XFP MSA Rev 4.5 Compliant ¨ Data rate from 9.95Gbps to 11.1Gbps ¨ No Reference Clock required ¨ Cooled EML and APD receiver ¨ Maximum link length up to 80km (1600ps/nm@G652 fiber) ¨ Low Power Dissipation 3.5W Maximum ¨ XFI and lineside loopback Mode Supported ¨ -5oC to 70oC Operating Case Temperature ¨ Diagnostic Performance Monitoring of module temperature, Supply Voltages, laser bias current, tramit optical power, and receive optical power ¨ RoHS6 compliant (lead free) Applicatio ¨ SONET OC-192& SDH STM 64 ¨ CWDM 80km 10G Ethernet ¨ CWDM 80km 10G Fiber Channel ¨ CWDM Networks ¨ CWDM 80km 10G Ethernet with FEC...
上海伯唐通信设备有限公司

1.25G SFP Optical Transceiver with DDM mornitor

60.00
2024/1/22 9:34:10
产品简介:FEATURES: l Up to 1.25Gb data links l Hot-pluggable SFP footprint l 1310nm Fabry-Perot laser tramitter l Duplex LC connector l Compliant with SFP MSA and SFF-8472 l Digital Diagnostic Monitoring(DDM):Internal Calibration or External Calibration l Very low jitter l No Rate Select input required for Fiber Channel 1x/2x Operation l Up to 20km on 9/125μm SMF l Metal enclosure, for lower EMI l Single 3.3V power supply l Low power dissipation <700mW typical l CWDM is also Available l Class 1: FDA/IEC60825-1 Laser Security APPLICATIO: l Gigabit Ethernet l 1x Fiber Channel l Switch to Switch interface l Switched backplane applicatio l Routeerver interface l Other optical tramission systems Description: BDTRP413L1SD-20 Small Form Factor Pluggable (SFP) traceive are compatible with the Small Form Factor Pluggable Multi-Sourcing Agreement (MSA).They comply with laser safety standard IEC-60825 and Ethernet standard IEEE802.3z 1000Base-LX/LH and IEEE802.3ah. The traceiver coists of two sectio: The tramitter section incorporates a FP laser. the receiver section coists of a PIN photodiode integrated with a tra-impedance preamplifier (TIA). All modules satisfy class I laser safety requirements. The optical output can be disabled by a TTL logic high-level input of Tx Disable. Tx Fault indicates that degradation of the laser. Loss of ** (LOS) output indicates the loss of an input optical ** of receiver. The SFP module can be compatible with other brand switch devices like Cisco,Huawei etc.The SFP module has the function of AGC (Automatic Gain control without attenuator). Optical Characteristics (TOP = 0 to 70℃, VCC = 3.00 to 3.60 Volts)...
上海伯唐通信设备有限公司

155M 2.67Gbps ESFP Optical Transceiver

100.00
2024/1/22 9:34:10
产品简介:Features ¨ 155Mbps~2.67Gbps bi-directional data links ¨ 1550nm DFB laser and APD photo detector for 80km tramission ¨ Compliant with SFP MSA and SFF-8472 with duplex LC receptacle ¨ Digital Diagnostic Monitoring:Internal Calibration or External Calibration ¨ Compatible with RoHS ¨ +3.3V single power supply ¨ Operating case temperature: Standard : 0 to +70°C Extended : -20 to +85°C Applicatio ¨ SDH STM-16 and SONET OC-48 system ¨ 2X Fiber Channel ¨ Switch to Switch interface ¨ Switched backplane applicatio ¨ Routeerver interface ¨ Other optical tramission systems Description The ESFP traceive are high performance, cost effective modules supporting multi-rate of 155Mbps~2.67Gbps and 80km tramission distance with SMF. The traceiver coists of three sectio: a DFB laser tramitter, a APD photodiode integrated with a tra-impedance preamplifier (TIA) and MCU control unit. All modules satisfy class I laser safety requirements. The traceive are compatible with SFP Multi-Source Agreement (MSA) and SFF-8472. For further information, please refer to SFP MSA....
上海伯唐通信设备有限公司

155M SFP Optical Transceiver

55.00
2024/1/22 9:34:11
产品简介:Features: ?Hot-Pluggable, Duplex LC Connector ?Single +3.3V Power Supply ?LVPECL Data Interface ?850/1310/1550nm VCSEL/FP/DFB, SM/MM Fiber Optional ?Eye Safety, Designed to Meet Laser Class1 ?Compliant with Telcordia (Bellcore) GR-468-CORE Application: ?Switch to switch interface ?High speed I/O for file serve . ?Bus exteion applicatio Description: The Small Form Factor Pluggable (SFP) traceive are compatible with the Small Form Factor Pluggable Multi-Sourcing Agreement (MSA). The SFP traceiver supports dual data-rate of 155MGbps and from 20km tramission distance with SMF...
上海伯唐通信设备有限公司

3Gbps Video SFP Optical Transceiver

100.00
2024/1/22 9:34:12
产品简介:Features HD-SDI SFP Traceiver available SD-SDI SFP Traceiver available 3G-SDI SFP Traceiver available SMPTE 297-2006 Compatible. Metal enclosure for Lower EMI 1310nm DFB laser and PIN photodetector Compliant with SFP MSA and SFF-8472 with duplex LC receptacle Digital Diagnostic Monitoring: Compatible with RoHS +3.3V single power supply Operating case temperature: Standard : 0 to +70°C Industrial : -40 to +85°C Applicatio SMPTE 297-2006 Compatible Electrical-to-Optical Interfaces. HDTVDTV Service Interfaces. Description The SFP traceive are high performance, cost effective modules supporting dual data-rate of 3Gbps and 20km tramission distance with SMF. The traceiver coists of three sectio: a DFB laser tramitter, a PIN photodiode integrated with a tra-impedance preamplifier (TIA) and MCU control unit. All modules satisfy class I laser safety requirements. The traceive are compatible with SFP Multi-Source Agreement (MSA) and SFF-8472. For further information, please refer to SFP MSA....
上海伯唐通信设备有限公司

EM-70/eX 可编程电流放大器 Electro-Optical Systems

1000.00
2024/2/6 15:29:21
产品简介:我司代理Electro-Optical Systems公司的各系列可编程电流放大器, 温馨提示: 本公司所售商品,因货品特殊,单价上下会有部分浮动。 另外,大多商品可在当天或是第二天发货,部分有较小起订量和货期要求...
深圳市康力华光电技术有限公司

Blackmagic Micro Converter系列转换卡Optical Fiber 12G

1350.00
2020/4/19 15:01:44
产品简介:Blackmagic Micro Converter系列转换器采用极其小巧设计,是一款广播级高品质视频转换器,可从事SDI到HDMI以及HDMI到SDI的转换工作。该系列将微型化机身和耐久设计融于一体,小到足以部署在任何位置,可巧妙隐藏且不易察觉!它们拥有HDMI和专业的3G-SDI接口,支持所有SD和HD格式且高可达1080p60,并且具备USB供电方案,能从大屏幕电视机或笔记本电脑获得电源,无需连接墙面插座即可运行!购买Blackmagic Micro Converter系列时,您可以选择产品是否内附AC电源适配器,以便根据自身需要选购合适的型号!    隆重推出Micro Converter BiDirectional SDI/HDMI可同时实现SDI转HDMI以及HDMI转SDI双向转换,同时处理任何SD 或HD格式   Micro Converter BiDirectional SDI/HDMI是迄今为止业界小型的广播级双向视频转换器!如今可实现SDI到HDMI以及HDMI到SDI的同时转换,支持SD上至1080p60 HD在内的任意格式组合!每个转换方向都可以是不同的SD或HD视频格式,将两款转换器合二为一!多速率3G-SDI输轻松胜任各类应用环境 入和输出连接可兼容A级和B级在内的几乎所有专业级广播设备,甚至可以自动检测到所有SD和HD格式!强悍的金属设计是现场制作和广播场合的完美选择。此外,其尺寸小巧可隐藏于任何拍摄场合,便于携带到任意地点,甚至还可以通过USB进行供电!   拥有广播级品质的袖珍型转换器!   Blackmagic Micro Converter设计精巧,可以安装到任何位置使用!您可以将它放入电脑包四处携带,还可以在户外直播车内使用,也可以装入航空箱。不论何种应用环境,这几款专业的广播级优质转换器都能够巧妙隐藏于现场,不易被观众察觉。它们十分适合用于新闻播报类制作,以及周围部署有多台屏幕和摄像机的现场活动,甚至还能应用到电视节目当中,为部署在现场的大屏幕电视机提供信号! 微型化设计   专业广播级转换器   Blackmagic Micro Converter不同于其他小型SDI转换器,它将极高品质的广播级技术注入到微型化的坚固金属机身之中,专业设计值得您的信赖!这款转换器搭载标准的3G-SDI以及HDMI等众多专业接口,并设有两个LED状态提示灯,能帮助您确认电源和视频信号的连接情况。此外,Blackmagic Micro Converter还能通过其自带的USB接口来获得电源。这意味着您可以通过USB接口从电视机或笔记本电脑获得电源。您还可以选购配有AC电源的Blackmagic Micro Converter,该型号配备4个不同的AC插座转换器,方便您连接电源插座。   标准尺寸接口充分利用您手头已有的线缆!   Blackmagic Micro Converter在精简小巧的同时,依然配备标准尺寸的3G-SDI和HDMI接口!而且,这些SDI接口均支持多速率,因此能兼容SD和HD-SDI设备。为了获得大兼容性,这些转换器还同时支持A级和B级3G-SDI设备。Micro Converter SDI to HDMI型号还配有一路SDI环通输入接口。Micro Converter HDMI to SDI型号则配备两路3G-SDI输出,可连接到切换台、矩阵以及监视器等众多设备!   Blackmagic Micro Converter是专业转换器系列的其中一员,这一系列涵盖了众多先进转换器型号,并有着海量功能和转换类型。   Blackmagic Mini Converter系列3G-SDI Mini Converte较Micro Converter而言更加先进,这是因为它们拥有平衡模拟和AES/EBU音频、冗余SDI输入、上/下变换以及1080PsF24/23.98等众多功能。这一转换器系列中设有光纤、SDI信号分配、模拟视频、嵌入音频等多款型号!   该系列拥有Mini Converter系列6G-SDI Mini Converte的全部功能,更搭载6G-SDI技术,并支持所有SD、HD和Ultra HD格式,高可达2160p30。此外,您还能获得Ultra HD到HD下变换等功能。该系列中的SDI to HDMI型号带有即时锁定功能,可在切换或连接输入时使HDMI显示器保持锁定状态。...
北京迪蓝科技有限公司

权恒光音频光纤线TOSLINK数字光纤光缆音响连接线OPTICAL接口工厂直销可定制进口纤芯

1.60
2020/11/22 23:13:14
产品简介:TOSLINK是东芝连接(Toshiba Link)的缩写,也是一种标准光学数字音频接口,日本厂商在CD机、MD机上普遍采用。用于在各种器材之间,通过一种光导体,利用光作载体来传送数字音频信号(左右声道或多声道)。TOSLINK可以使用塑料光纤做塑料光纤音频跳线。常用标准的直径为?1.0mm、数值孔径(NA)0.5的PMMA芯塑料光纤,护套为(阻燃)PVC 产品特点:较小传输损耗,误码率(只有2%左右) 体积小,柔软可绕性好、抗冲击 安装简便、成本低廉 重量轻、不导电、性能稳定 排除无线电波和电磁干扰 数据传输效率高、保密性高 适用范围: 多媒体音响系统 高清影音播放系统、MD播放器 回音壁,家庭影院,电视机...
深圳权恒光电技术有限公司
X